We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out communications with the pump and ScreenLogi...

Pentair easy touch troubleshooting. Things To Know About Pentair easy touch troubleshooting.

Remotely manage from a Mac® Computer or PC using the ScreenLogic2 Interface application. Easily change, track and monitor history of pH and ORP levels when using the IntelliChem® Water Chemistry Controller with IntelliTouch® or EasyTouch® automation systems. ScreenLogic2 app now allows full-color lighting control for both IntelliBrite® LED ...Unless your dishwasher is part of the massive Bosch dishwasher recall, your unit should last you a decade or more. This is, of course, if you take good care of it. Here are some tips on how to troubleshoot your dishwasher.We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out the input/outputs on my board. This is an …INFORMATION AT YOUR FINGERTIPS. Stay smart, connected and protected with the Pentair Home app. This product is one of a range of connected products from Pentair …Consult Pentair Water Pool and Spa, Inc. with any questions regarding this product. This product is intended for use in swimming pool applications only. ... EasyTouch Wireless Control Panel, 8 circuits (P/N 520547) iS4 Four-Function Spa-Side remote, 150 ft. cable (P/N 520094)

The heater display board gives a CEr indicator (communication problem). Likewise, my 9-year-old Pentair EasyTouch remote control system in the house now indicates "NO COMM." A tech recently replaced the AquaCal display board with a new-style board, and before the circuit breaker failed the heater had been working well.PENTAIR AQUATIC SYSTEMS 1620 HAWKINS AVE., SANFORD, NC 27330 • (919) 566-8000 10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 • (805) 553-5000 WWW.PENTAIRPOOL.COM All Pentair trademarks and logos are owned by Pentair, Inc. Pentair Aquatic Systems™, EasyTouch ®, IntelliTouch, and

The heater display board gives a CEr indicator (communication problem). Likewise, my 9-year-old Pentair EasyTouch remote control system in the house now indicates "NO COMM." A tech recently replaced the AquaCal display board with a new-style board, and before the circuit breaker failed the heater had been working well.With SunTouch, your pump and heater automatically run whenever you want, for as long as you want, so your pool and spa are always warm and inviting. Or, switch to manual mode for those spontaneous plunges. Either way, you’re in complete control. One-touch function—no complicated routine to memorize. Ability to program pool and spa and 2 ...

If you have questions about ordering Pentair replacement parts, and pool products, please use the following contact information: CUSTOMER SERVICE / TECHNICAL SUPPORT Customer Service (8 A.M. to 4:30 P.M. — Eastern and Pacific Times) Phone: (800) 831-7133 Fax: (800) 284-4151 Web site Visit www.pentair.com for more information about …May 6, 2021 · I bought this home about ten years ago and the pool was fairly new and came with a four button Pentair Easytouch. It worked fine for the next nine years. Occasionally, the remote wouldn't even come on, but tapping the back of the battery box would seem to fix the problem. This week, it did that but wouldn't come at all. INTELLICHEM ® Water Chemistry Controller Installation and User s Guide ii IMPORTANT WARNING AND SAFETY INSTRUCTIONS WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the house before drilling intoThese Pentair MasterTemp 400 Problems relating to temperature are explored below. i) No Heat. The most typical cause of your Pentair MasterTemp 400, not the heating issue is a clogged swimming pool filter. Solution: Low water flow is the cause of up to 70% of all ‘My heater won’t heat’ service calls.

From https://www.justanswer.com/ythiJustAnswer Customer: I have a pentair easy touch that is reading "no comm" after power went out to house during storm.Jus...

The QuickTouch II receiver is connected to the EasyTouch, IntelliTouch and SunTouch system via a four-conductor communication cable. For receiver antenna location, see page 13. To connect the receiver cable to EasyTouch or IntelliTouch load center: 1. 2. Unlatch the load center front door spring latch, and open the front door. 3.

IntelliBrite LED lights are fully compatible with Pentair IntelliTouch® and EasyTouch ... Use the following tips to help to resolve problems that might occur while operating the IntelliBrite Controller. Both of the LEDs are flashing. The IntelliBrite Controller has detected that the load has exceeded the maximum allowable wattage or the output is shorted out 1. Switch …Manuals and User Guides for Pentair EasyTouch 8. We have 2 Pentair EasyTouch 8 manuals available for free PDF download: User Manual, Installation Manual Pentair …This covers the general concepts of how to wire a Pentair Easytouch Automation center and load panel. Pentair Easy touch control system. Pentair Easy touch p...Posted January 1, 2018. Pentair assigned a local tech to inspect. Turns out the pool builder improperly wired the variable speed pump and fried the controller. He then disconnected the wiring and stuffed it in the master controller box (bare wires and all), but he left the plug connected to the pump. The pump could not receive instructions from ...As, It could be you took a lightning hit and it took out the relay drivers as well as your com port. Step 1 in troubleshooting a com port failure on an EasyTouch is to connect just the pump (And nothing else) to the J20 com port. Then go look at the pump and see if the display shows "Display not active". It should.

1. With the power off I would disconnect ScreenLogic from the EasyTouch's com port. Disconnect the SWCG by unplugging the cable at the EasyTouch. Disconnect the pump from the EasyTouch by unplugging the cable at the pump. 2. Turn the power on to the pump and test the pump to make sure it responds to commands from the pump's …INFORMATION AT YOUR FINGERTIPS. Stay smart, connected and protected with the Pentair Home app. This product is one of a range of connected products from Pentair that gives you command of your …Pool & Spa Equipment. Pool & Spa. Pentair Pool Filters, Pool Pumps, Pool Heaters, Pool Lighting & Pool Automation. The ScreenLogic2 Interface allows you to control the key functions of a pool or spa using the IntelliTouch® and EasyTouch® control systems. You can remotely manage, monitor and control via mobile device. Easily change, track and monitor history of pH and ORP levels when using the IntelliChem® Water Chemistry Controller with IntelliTouch® or ...The EasyTouch PL4 system is designed for a single body of water, while the EasyTouch PSL4 system is designed to control a pool and spa combination. These systems work with the ScreenLogic2® Interface for full control via computer or mobile devices. Controls filter and pump functions, plus 3 additional pieces of equipment, allowing you control ... Heat pump troubleshooting guide for Pentair pool heaters. Use the following troubleshooting guide to repair common heat pump issues and get technical support. Call Us Nationwide: 1-800-741-9956. West: 213-291-9276 Southwest: 214-764-8551 Midwest: 312-229-0026 Northeast: 631-223-7175 Southeast: 239-247-5878 or 954-866-1644. …replacement, only use Pentair replacement battery (P/N 520815Z). Sufficient charge left in the batteries to operate device. Three solid bars indicate ample battery charge. During battery recharge, bars scroll right to left. Batteries will deplete soon. The power plug icon displays when the battery is fully charged and the MobileTouch controller ...

Nov 10, 2018. #1. Hello, We had an inground pool and new equpment pad installed just about 3 and a half years ago. We are now suddenly experiencing an issue where the 3AMP switch in the top right of the control box, trips upon power on (shortly after - LCD panel lights, and a couple of the buttons show power - but then the 3AMP trips).Sump Pump Troubleshooting FAQ. Go Back. Utility Pump Info FAQ. Go Back. Pentair WellMate FAQs. Go Back. Our Impact. Go Back. Our Impact. Go Back. Project Safewater. Go Back. Honduras; India; Kibera; Team Pentair. Go Back. Pentair Philanthropy. Go Back. Pentair Social Responsibility Targets. ... PENTAIR WARRANTY = PEACE OF MIND. …

If you have any questions please contact us through our website at: https://www.poolspecialists.com/#1 My remote is not communicating with system. My batteries are good where do I start? Report JoyfulNoise TFP Expert Platinum Supporter May 23, 2015 23,501 Tucson, AZ Pool Size 16000 Surface Plaster Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-60 Dec 27, 2015 #2 Reset the EasyTouch panel. See if that corrects the problem.Knowing how to troubleshoot issues with your vacuum cleaner is one sure way of extending its service life and getting the most bang for your buck. It does suck to have a vacuum cleaner that doesn’t suck.If your fridge isn’t keeping your food cold, it can be a hassle to figure out what’s wrong. Fortunately, there are some simple steps you can take to troubleshoot the problem and get your fridge back up and running. Here’s an easy guide to t...! " # $%& 2 -1 9 -0 4 / ( )* +,--.' - . ) ! /0 1 &/; 2 4 0 < . : &) . 1 ! . : w a r n in g r is k o f e l e c t r ic a l s h o c k o r e l e c t r o c u t io n Jun 16, 2020 · Go out to the outside control unit, and with the pump running, and in the pool mode Auto, push the Aux 3 button.. Your Intake valve should stay in the pool mode and the Return valve should rotate to the Spa mode. >>> IT WORKS!!!! one of the valve changed position and the spa jets were working. Mar 26, 2022 · These Pentair MasterTemp 400 Problems relating to temperature are explored below. i) No Heat. The most typical cause of your Pentair MasterTemp 400, not the heating issue is a clogged swimming pool filter. Solution: Low water flow is the cause of up to 70% of all ‘My heater won’t heat’ service calls.

3. put the neg/black probe on the red wire. 4. put the pos/red probe on the terminal that the wire was connected to... connecting the probes will "complete the circuit" and the current will flow "through" the meter, giving you a measurement. If it's still no-go, pm me and I can test it for you.

I have a pentair intelliflo vs with the ScreenLogic connect app easy touch control. Worked fine yesterday, today says lost communication with the pump. The lights work but can’t get the pump to turn on. You can hear it clicking on or trying to, at the easy touchcontroller box but nothing from the pump. I have disconnected and reconnected the ...

A local Pentair Installer told me that the POOL must be active for the entire duration of the day - AND - it must be programmed to run at the lowest speed. I have called Pentair three times in the last week - one call lasted 2 hours and 35 minutes and the guys there are not impressing me!!! Hope someone here can help me to resolve this. Thanks ...Carrier thermostats can be troubleshooted by looking for common problems and addressing these problems one at a time until the problem is fixed. Some common problems may include a system that is not heating or cooling enough or a system tha...Jan 13, 2017 · This means that the only thing the EasyTouch will do is to turn on/off the main power to the pump. All the timing for when the pump comes on, and at what speed, is being done internal to the pump. For example say you wanted the pump to run at 1,000 RPM from 8 am until 10 am and then at 1,500 from 10 am until 11 am. Place the EasyTouch control panel face down on a flat clean surface. Remove the six screws securing the battery cover. Set the cover aside. Screw (6x) Battery cover Easy Touch Control Panel (rear view) EasyTouch Wireless Control Panel Installation and User’s Guide f8 Installing batteries (Continued) 2.A systematic approach to solving the problem is often the best way to track down and then correct engine problem, according to Kohler Power. The first step of troubleshooting to figure out what’s wrong with a Kohler engine is identifying th...Pentair Pool Filters, Pool Pumps, Pool Heaters, Pool Lighting & Pool Automation Call Us: 1-800-831-7133 3. Tampa. Mar 25, 2023. #1. My Pentair EasyTouch 8 system had an alert to "Clean Salt Cell". I removed the Intellechlor salt cell and cleaned it with acid (as I have done dozens of times with my old pool, this was the first time on my new pool with the new system). After about ten minutes, there was no more bubbling so I reconnected the cell.Feb 9, 2020 · The following problems can be caused by faulty communication: pressing a button on a remote or indoor controller does nothing. an Intelliflo pump won't run the schedule. screenlogic can't control the system. communication timeout errors show on the intellitouch indoor panel. an Easytouch wireless remote or indoor panel shows "No Comm". If you have something else on the buss, like ScreenLogic or a SWG and they work, then the problem will not be the EasyTouch's communications buss. So, step one is to ensure the date cable is connected at the pump and inside the EasyTouch. Step two is to see if the pump's display reads "Display not Active."Posted January 1, 2018. Pentair assigned a local tech to inspect. Turns out the pool builder improperly wired the variable speed pump and fried the controller. He then disconnected the wiring and stuffed it in the master controller box (bare wires and all), but he left the plug connected to the pump. The pump could not receive instructions from ...

Now, you can make it even more convenient to run your pool, spa or combination with the added ease of a wired or wireless remote. Plus, you can program your equipment for optimal energy efficiency. Allows easy upgrade to EasyTouch® Automation functionality for the following Compool® Systems: CP3400, CP3600, CP3800, CP3810, CP1000*, CP2000 ... Sump Pump Troubleshooting FAQ. Go Back. Utility Pump Info FAQ. Go Back. Pentair WellMate FAQs. Go Back. Our Impact. Go Back. Our Impact. Go Back. Project Safewater. Go Back. Honduras; India; Kibera; Team Pentair. Go Back. Pentair Philanthropy. Go Back. Pentair Social Responsibility Targets. ... Pentair Pool Filters, Pool Pumps, Pool Heaters, …Jun 21, 2016 · Jun 21, 2016. #1. We have a Pentair EasyTouch 8 control system for our in-ground pool and this past weekend, following a fairly severe electrical storm, neither the filter nor cleaner pump was working. When I went to investigate I found that the only apparent problem was that the low voltage circuit breaker that is labeled "Relays" was open. Instagram:https://instagram. spn 5541 fmi 4stihl fs45 weed eater string replacementflowering bouquet hypixelwilding wall beds Go back and start with step 1. Running the protocol adapter update tool will insure that you have the latest firmware installed onto the PA. Note: if you do need to run the updater tool due to a version mismatch, you may need to run it twice. Don't know why, its just what Pentair says. unblocked games ez 67luxy extensions Go back and start with step 1. Running the protocol adapter update tool will insure that you have the latest firmware installed onto the PA. Note: if you do need to run the updater tool due to a version mismatch, you may need to run it twice. Don't know why, its just what Pentair says. boudin bakery south coast plaza The next thing you need to do is assign the valve to a circuit.. and set the pump speed for that circuit. You can then schedule the waterfall if you want or just manually use an icon to turn the valve on and off. 1. Find an unused Feature Circuit and rename it "Waterfall". Leave Circuit function as generic.The QuickTouch II receiver is connected to the EasyTouch, IntelliTouch and SunTouch system via a four-conductor communication cable. For receiver antenna location, see page 13. To connect the receiver cable to EasyTouch or IntelliTouch load center: 1. 2. Unlatch the load center front door spring latch, and open the front door. 3.